{"id":3331,"date":"2021-08-07T15:36:04","date_gmt":"2021-08-07T11:06:04","guid":{"rendered":"https:\/\/davvarenergy.com\/?page_id=3331"},"modified":"2022-06-25T16:28:42","modified_gmt":"2022-06-25T11:58:42","slug":"speed-pickup-sensors","status":"publish","type":"page","link":"https:\/\/davvarenergy.com\/en\/products\/speed-pickup-sensors\/","title":{"rendered":"Speed Pickup Sensors"},"content":{"rendered":"

[vc_row][vc_column]

<\/div>
<\/div>

Speed Sensors Magnetic Pickup<\/strong><\/span><\/p>\n

For \u00a0sensing rotational Speed<\/strong><\/span><\/p>\n

To control the rotational speed of a prime mover, speed controls compare actual speed to desired, or set, speed. When a magnetic material (usually a gear tooth driven by shaft) passes through the magnetic field at the end of the magnetic pickup, a voltage is developed. The frequency of this voltage is measured by the speed control.<\/span><\/p>\n

Installation<\/strong><\/span><\/p>\n

Magnetic speed pickup is usually mounted radially to the gear, either through the housing or on a rigid bracket. Sensor must be mounted off the face of the gear, be sure to check For \u00a0gear end play in addition to gear run out. Petro davvar energy have installation manuals For \u00a0each sensor.<\/span><\/p>\n

Types of Magnetic pickups<\/strong><\/span><\/p>\n

Petro Davvar Energy is manufacturing Magnetic pickups in different lengths and mounting thread sizes according to API 670. See some of Our \u00a0magnetic pickups require a connector which you can see on catalog.<\/span><\/p>\n

Setting the Gap<\/strong><\/span><\/p>\n

The gap between the end of the sensor and the gear tooth is set at 0.25 to 1.4 mm (0.010 to 0.055 inch) at the closest point. The sensor will be damaged if it touches the moving gear. A properly installed sensor will provide as much as 50 Vac (rms); most turbine controls require a minimum of 1.5 Vac at the lowest speed. Voltage decreases as the sensor is moved farther from the gear. If the gap between the pickup and the gear cannot be measured directly, it can be determined by counting the number of turns the pickup is backed away from the gear. One full turn counterclockwise will move the sensor out 0.055 inch (1.4 mm For \u00a0example For \u00a0Solar centaur gas turbine).<\/span><\/p>\n

\"\"\"\"\u00a0<\/strong><\/span><\/p>\n

Our \u00a0Sensor Have IP67 Certificates and EX ecIIA T4 Approvals By EPIL Co. \u00a0<\/span><\/p>\n

We Have Some Gas Turbine Speed Pick Up In Stock Such As\u00a0 :<\/span><\/p>\n

Ruston Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

Solar (MDG 1200 & 4000 & 4500) Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

Nouvo Pignone Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

Rolls Royce Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

Werkspoor Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

Sulzer Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

GEC Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

General Electric Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

Coolper Besmer Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

Siemens Gas Turbine Magnetic Speed Pick Up.<\/span><\/p>\n

To download the catalog of this product, please click here<\/span><\/a><\/strong>.<\/span><\/p>\n<\/div><\/div><\/div>

<\/div>[\/vc_column][\/vc_row][vc_row][vc_column]
<\/div><\/div><\/div>
<\/div>
<\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=”1\/6″ offset=”vc_col-md-4″]

Nuovopignone Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>
<\/div>[\/vc_column][vc_column width=”2\/3″ offset=”vc_col-md-4″]

Rolls Royce Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>
<\/div>[\/vc_column][vc_column width=”1\/6″ offset=”vc_col-md-4″]

GEC Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>
<\/div>[\/vc_column][\/vc_row][vc_row][vc_column offset=”vc_col-md-4″]

GE Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>
<\/div>[\/vc_column][vc_column offset=”vc_col-md-4″]

Werkspoor Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>
<\/div>[\/vc_column][vc_column offset=”vc_col-md-4″]

Solar Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>
<\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=”1\/3″]

Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>[\/vc_column][vc_column width=”1\/3″]

Solar Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>[\/vc_column][vc_column width=”1\/3″]

Sulzer Gas Turbine Magnetic Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=”1\/3″]

Gas Turbine Speed Pick Up<\/h3>
\"\"<\/div><\/div><\/div>[\/vc_column][vc_column width=”1\/3″][\/vc_column][vc_column width=”1\/3″][\/vc_column][\/vc_row][vc_row][vc_column]
<\/div>
<\/div>[\/vc_column][\/vc_row][vc_row full_width=”stretch_row” css=”.vc_custom_1569576715902{background-image: url(https:\/\/davvarenergy.com\/wp-content\/uploads\/2019\/09\/bg1.jpg?id=1266) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}”][vc_column]
<\/div>
<\/div>
<\/div>
<\/div><\/div><\/div>
<\/div>
<\/div><\/div><\/div>
<\/div>
<\/div>[\/vc_column][\/vc_row][vc_row full_width=”stretch_row” css=”.vc_custom_1569600133635{background-color: #e9e9e9 !important;}”][vc_column]
<\/span>
[vc_row_inner equal_height=”yes”][vc_column_inner width=”1\/2″ css=”.vc_custom_1569859578343{background-color: #1b2459 !important;}” offset=”vc_col-xs-12″]
<\/div>
\n
Need Advice<\/span><\/span><\/strong><\/span><\/div>\n
Feel Free to Contacts Us<\/span><\/strong><\/span><\/div>\n<\/div>\n<\/div><\/div><\/div>
<\/div>

\u00a0<\/span><\/p>\n<\/div><\/div><\/div>

<\/div>[\/vc_column_inner][vc_column_inner width=”1\/2″]
<\/div>
<\/div>
<\/div>
<\/div>
\n

<\/p>

    <\/ul><\/div>\n
    \n
    \n\n\n\n\n\n\n<\/div>\n

    <\/span><\/p>\n

    <\/span><\/p>\n

    <\/span><\/p>\n